Page view 18
28
Troubleshooting
Messages / Warnings
CAL
Typically indicates that defaults were entered by powering up with the CAL and
“-” buttons held, but calibration mode was not entered and exited. Cycling power
will not clear the bad CAL message, it can only cleared by entering and exiting
calibration mode.
Low Power. Check all power and ground connections.
One or more Seed Bins are near empty.
Warn LED ashes when the Rate error is over 10% in AUTO or if no ow input
(when there should be) in MAN. On steady when in CALIBRATE or
“SPECIAL”CALIBRATE or Test Speed.
“Special” Calibration mode is active. Appears when entering Special Calibration
mode (hold AUTO/MAN and CAL buttons while turning console on).
The message alerts the user that the currently selected counter will be cleared
if held for 2 seconds. Also serves as a reminder to use “+” button to select
counters.
Counters (DISTANCE or AREA or WEIGHT) have overowed their maximum.
RESET (see pages 26-27) to clear counters and resume counting.
Had an Emergency Stop. Check Seed Shaft (Flow) Sensor. Cleared by
turning all used Sections o, going to HOLD or cycling power.
Has loaded Default Cal factors (appears when default calibration factors are
loaded by holding CAL and “-” buttons while turning the console on).
In RATE mode and should have ow but no Flow is detected.
In Rows/Section Cal Mode, and no Sections are turned on.
In RATE mode and have no Speed, regardless of all other conditions.
In METER CAL TEST but have not yet enter a Test Speed.
Displays for 1.5 seconds upon powering up.