Drill Master 94436 User Manual

Browse online or download User Manual for Power drills Drill Master 94436. Dual Abutment

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 2

PROSTHESIS MANUALTypes of Abutment 11Prosthetic Procedure 1 12Abutment Level- Solid / Dual Abutment 13Abutment Level- SCA Abutment 16Prosthetic Proc

Page 3 - SURGICAL MANUAL

SimpleLine ll Surgical / Prosthesis Manual11Types of AbutmentAbutment LevelOne-PieceCylinderTwo-PiecesFixture LevelOctaScrew AbutmentDual Milling Abut

Page 4 - Surgical Drill Sequence

SimpleLine ll Surgical / Prosthesis Manual12Cemented RestorationProsthetic Procedure 1Impression Technique and Restoration SelectionSolid / Dual / SCA

Page 5 - Fixture Installation

SimpleLine ll Surgical / Prosthesis Manual13Abutment Level-Solid / Dual AbutmentClinical ProcedureHealing Abutment Solid Abutment orDual AbutmentAbutm

Page 6 - Fixture Connection

Abutment Level-Solid / Dual AbutmentSimpleLine ll Surgical / Prosthesis Manual14Laboratory ProcedureLab Analog Connection Cylinder Crown Wax-upFinal R

Page 7

SimpleLine ll Surgical / Prosthesis Manual15Abutment Level-Solid / Dual Abutment[Multiple Units]Shave off the extended margin by usingthe rubber wheel

Page 8 - Surgical Kit Maintenance

Abutment Level-SCA AbutmentSimpleLine ll Surgical / Prosthesis Manual16[Multiple Units]Clinical ProcedureFixture installation. Choose SCA abutment (Oc

Page 9 - Warnings

SimpleLine ll Surgical / Prosthesis Manual17Abutment Level-SCA Abutment[Multiple Units]Laboratory ProcedureLab Analog Connection Cylinder Crown Wax-up

Page 10 - PROSTHESIS MANUAL

SimpleLine ll Surgical / Prosthesis ManualAbutment Level- SCA Abutment18[Multiple Units]Shave off the extended margin by usingthe rubber wheel.Metal f

Page 11 - Types of Abutment

SimpleLine ll Surgical / Prosthesis Manual19Prosthetic Procedure 2Dual / SCA / Dual Milling / Angled / Direct-Casting /Metal-Casting / Temporary Abutm

Page 13 - Abutment Level

Fixture Level[Pick-up Type]-Dual AbutmentSimpleLine ll Surgical / Prosthesis Manual20[Multiple Units]Clinical ProcedureHealing Abutment Impression Cop

Page 14

SimpleLine ll Surgical / Prosthesis Manual21Fixture Level[Pick-up Type]-Dual Abutment[Multiple Units]Laboratory ProcedureLab Analog Connection Assembl

Page 15

Fixture Level[Pick-up Type]-Dual AbutmentSimpleLine ll Surgical / Prosthesis Manual22[Multiple Units]Final prosthesis. Use positioning jig to transfer

Page 16

SimpleLine ll Surgical / Prosthesis Manual23Fixture Level[Transfer Type]-Dual Abutment[Multiple Units]Clinical ProcedureHealing Abutment Impression Co

Page 17

Fixture Level[Transfer Type]-Dual AbutmentSimpleLine ll Surgical / Prosthesis Manual24Laboratory ProcedureLab Analog Connection Assemble theDual Abutm

Page 18

SimpleLine ll Surgical / Prosthesis Manual25Fixture Level[Transfer Type]-Dual AbutmentCompletion of wax-up. Metal framework. Final prosthesis build-up

Page 19 - Prosthetic Procedure 2

Fixture Level-SCA Abutment SimpleLine ll Surgical / Prosthesis Manual26Clinical ProcedureHealing AbutmentFixture Level Impression Pick-up TypeOpen Tra

Page 20 - Fixture Level

SimpleLine ll Surgical / Prosthesis Manual27Fixture Level-SCA AbutmentAssemble the SCA abutment. If deemed necessary, abutment milling is possible.Fab

Page 21

Fixture Level-Dual Milling AbutmentSimpleLine ll Surgical / Prosthesis Manual28Connect analogs with theset impression material.Soft tissue modeling. C

Page 22

SimpleLine ll Surgical / Prosthesis Manual29Fixture Level-Dual Milling Abutment[Single Unit]Assemble the dual milling abutment. Milled the abutment to

Page 23

SURGICAL MANUALSurgical Drill Sequence 04Fixture Installation 05Fixture Connection 06Surgical Kit Maintenance 08Warnings 09

Page 24

Fixture Level-Angled AbutmentSimpleLine ll Surgical / Prosthesis Manual30[Single Unit]Impression coping with analog connections.Soft tissue formation

Page 25

SimpleLine ll Surgical / Prosthesis Manual31Fixture Level-Angled Abutment[Single Unit]Create the master model. Assemble the angled abutment. Milled th

Page 26

Fixture Level-Direct-Casting AbutmentSimpleLine ll Surgical / Prosthesis Manual32[Single Unit]Impression coping with analog connections.Soft tissue fo

Page 27

SimpleLine ll Surgical / Prosthesis Manual33Fixture Level-Direct-Casting AbutmentAssemble the direct casting abutment. Completed customized abutment.

Page 28

SimpleLine ll Surgical / Prosthesis Manual34Prosthetic Procedure 3Impression Technique and Restoration SelectionScrew AbutmentScrew-Retained Restorati

Page 29

SimpleLine ll Surgical / Prosthesis Manual35Abutment Level-Screw Abutment[Multiple Units]Select and seat an appropriate screwabutment with delivery ho

Page 30

SimpleLine ll Surgical / Prosthesis ManualAbutment Level-Screw Abutment36Laboratory ProcedureLab Analog Connection Cylinder Connection Modification Cr

Page 31

SimpleLine ll Surgical / Prosthesis Manual37Abutment Level-Screw AbutmentGold framework. Use the reamer to remove the "Lip" inthe interior o

Page 32

Cementation Repair Method (SCRP)SimpleLine ll Surgical / Prosthesis Manual38[Screw & Cement Retained Prosthesis]In light of Implant Prosthesis:• S

Page 33

SimpleLine ll Surgical / Prosthesis Manual39Cementation Repair Method (SCRP)[Screw & Cement Retained Prosthesis]Remove the screw completely withsc

Page 34 - Prosthetic Procedure 3

SimpleLine ll Surgical / Prosthesis ManualSurgical Drill Sequence0481012 14 163.4 3.8 4.34.3 4.8Final drillTap drillFirstguidedrillSecondguide drill

Page 35

SimpleLine ll Surgical / Prosthesis Manual40Prosthetic Procedure 4Impression Technique and Restoration TypeOverdenture ProcedureMini Ball and Socket A

Page 36

SimpleLine ll Surgical / Prosthesis Manual41PositionerTake impression for the production ofthe individual tray.Connect the Positioner Abutment ontothe

Page 37

SimpleLine ll Surgical / Prosthesis Manual42PositionerCreate holes for the placement of the metal sockets.Apply the resin into the holes and waituntil

Page 38

SimpleLine ll Surgical / Prosthesis Manual43Ball AttachmentAffix the impression coping on the Ball Abutment.Take the final impression with the prepare

Page 39

SimpleLine ll Surgical / Prosthesis Manual44Case 2Create holes for the placement of the female sockets.Apply the resin into the holes and waituntil it

Page 40 - Prosthetic Procedure 4

SimpleLine ll Surgical / Prosthesis Manual45Remove the Healing Abutment.Connect implant keeper with the fixtureand tighten it with 25~30 N‧cm.Implant

Page 41 - Positioner

SimpleLine ll Surgical / Prosthesis ManualMagnetic Attachment46Create holes for the placement ofthe magnets.Examine for interference between theinner

Page 44

Fixture InstallationSimpleLine ll Surgical / Prosthesis Manual05Final drill Ø4.3Final drill Ø4.8Ø4.8Ø6.5Final drill Ø4.3Final drill Ø4.8Tap drillØ4.8Ø

Page 45 - Magnetic Attachment

SimpleLine ll Surgical / Prosthesis ManualFixture Connection06Caution_ When opening the fixture package,hold it upright to avoid falling out ofthe fix

Page 46

SimpleLine ll Surgical / Prosthesis Manual07Removal of the Fixture Mount Removal Mechanism of the Fixture MountRun the hand-piece in reverse mode.Fix

Page 47

SimpleLine ll Surgical / Prosthesis Manual08Surgical Kit MaintenanceSterilization and Instrument Care Procedures • Please follow legal regulations, as

Page 48

SimpleLine ll Surgical / Prosthesis Manual09WarningsWarningsDental implant surgery and restoration involve complex dental procedures. Appropriate and

Comments to this Manuals

No comments